Skip to main content
  • Robot-Assisted Placement of Depth Electrodes Along the Long Axis of the Amygdalohippocampal Complex

    Final Number:
    205

    Authors:
    Kieu Tran MD; Alvin Chan BS; Sumeet Vadera MD

    Study Design:
    Other

    Subject Category:
    Emerging Technologies

    Meeting: 2016 ASSFN Biennial Meeting

    Introduction: Classically, transoccipital hippocampal depth electrode implantation requires a stereotactic headframe and arc and the patient to be placed in a seated or prone position, which can be cumbersome to position and uncomfortable for the surgeon. Robotic intracranial devices are increasingly being utilized for stereotactic procedures such as stereolectroencephalography (SEEG) but commonly require patients be placed in head-neutral position to perform facial registration. Here we describe a novel robotic implantation technique where a stereotactic intracranial robot is used to place bilateral hippocampal depth electrodes in the lateral position.

    Methods: Four patients underwent SEEG depth electrode placement, which included placement of bilateral hippocampal depth electrodes. Each patient was positioned in the lateral position and registered to the robot with laser facial registration. Trajectories were planned with the robotic navigation software, which then identified the appropriate entry points and trajectories needed to reach the targets. After electrode implantation, target localization was confirmed using computed tomography (CT).

    Results: Electrodes targeting the amygdalohippocampal complex were accurate and there were no complications in this group. An average of seven electrodes were placed per patient. Ictal onset was localized for each patient. All patients subsequently underwent temporal lobectomy; at 6 months, 3 patients were seizures and the 4th had a significant reduction in seizures burden.

    Conclusions: We have developed the Robot-Assisted Lateral Transoccipital Approach, which is an advantageous technique for placing bilateral amygdalohippocampal depth electrodes using robotic guidance. Benefits of this technique include fewer electrodes required per patient and ease of positioning compared with seated or prone positioning.

    Patient Care: Robotic assistance in stereotactic procedures could increase accuracy and precision by removing the potential for human error in stereotactic navigation, resulting in more effective therapy and increasing patient safety.

    Learning Objectives: By the conclusion of this session, participants should be able to do the following: 1) describe the indications for robotic assistance in potentially implanting depth electrodes; 2) discuss in small groups their thoughts on potential outcomes for robotic assistance in stereotactic procedures.

    References: