Skip to main content
  • Deep Brain Stimulation in Multiple Rooms: a Single-Surgeon Retrospective Comparison of Overlapping and Non-Overlapping Electrode Placements

    Final Number:
    344

    Authors:
    John Paul Sheehy MD; Tsinsue Chen MD; Michael Bohl MD; Michael Anthony Mooney MD; Zaman Mirzadeh MD PhD; Francisco A. Ponce MD

    Study Design:
    Clinical Trial

    Subject Category:

    Meeting: Congress of Neurological Surgeons 2018 Annual Meeting

    Introduction: Many surgeons utilize assistants to perform procedures in more than one operating room at a given time, a practice known as overlapping surgery. This single-surgeon retrospective analysis examines the effect of overlapping surgery on clinically relevant endpoints in deep brain stimulation (DBS) surgery for movement disorders.

    Methods: DBS electrode placements performed by the primary surgeon at the Barrow Neurological Institute were retrospectively evaluated. Recorded case times for each DBS surgery were evaluated for any overlap with another case of the primary surgeon on the same day. Stereotactic accuracy, operative duration, length of hospital stay, and rates of hemorrhage, wound-related complications, and hardware-related complications requiring a revision (e.g. post-operative high impedance) were noted and compared between overlapping and non-overlapping cases.

    Results: Of 324 cases, 141 were overlapping and 183 were non-overlapping. Stereotactic error, the number of brain penetrations per electrode, and post-operative length of stay did not differ significantly between overlapping and non-overlapping cases. There was also no significant difference when “asleep” DBS cases were considered as a separate subgroup. Mean operative duration was significantly longer in overlapping cases for the most common permutation of the procedure (asleep, bilateral electrode placement with a pulse generator; 190 minutes vs 170 minutes, p=0.004). Hemorrhage and wound-related complication rates did not differ significantly, but the rate of hardware-related complications requiring revision was significantly higher in the overlapping group (7/141 vs 0/183; p = 0.002).

    Conclusions: Stereotactic accuracy, brain penetration, hospital length of stay, hemorrhage rates and wound-related complication rates were comparable for overlapping and non-overlapping DBS electrode placements. Overlapping DBS electrode placements had a longer operative duration and demonstrated a higher rate of hardware-related complications requiring revision. Overlapping DBS surgery can be performed safely and accurately but attention to detail remains critical for optimal outcomes for this elective procedure.

    Patient Care: Recent controversies regarding overlapping surgery have been driven by concerns for patient safety on one side and patient access on the other. Meaningful clinical data evaluating the safety and efficacy of overlapping surgery for core neurosurgical procedures such as deep brain stimulation provides meaningful context to this ongoing debate, and identifies potential risks of overlapping surgery which might be proactively mitigated.

    Learning Objectives: By the conclusion of this session, participants should be able to: 1) Understand DBS surgery in the context of overlapping surgery. 2) Understand in which ways overlapping surgery scheduling did not affect patient outcomes in our series. 3) Describe possible pitfalls of overlapping surgery identified in our series.

    References:

We use cookies to improve the performance of our site, to analyze the traffic to our site, and to personalize your experience of the site. You can control cookies through your browser settings. Please find more information on the cookies used on our site. Privacy Policy