Skip to main content
  • Initial Experience Using a Three-dimensional (3D), High-definition (4K-HD) Video Microscope System

    Final Number:
    1124

    Authors:
    Jeffrey Steinberg MD; Jayson Sack MD; Robert Rennert MD; Dustin Hatefi; J. Scott Pannell MD; Michael L. Levy MD, PhD; Alexander A. Khalessi MD, MS, FAHA, FAANS

    Study Design:
    Laboratory Investigation

    Subject Category:

    Meeting: Congress of Neurological Surgeons 2016 Annual Meeting

    Introduction: The operative microscope and endoscope have significantly advanced modern neurosurgery. These devices’ technical limitations include sub-optimal optics, ergonomics, and maneuverability. A recently developed 3D, 4K video microscope operative system combines characteristics from the operative microscope and endoscope to provide a portable, high-definition operative experience. Existing exoscopes lack stereopsis with 2D monitors, thereby limiting their widespread adoption in neurosurgery.

    Methods: Assess dissection time and visualization of critical structures in a series of human cadaveric cranial neurosurgical approaches with the 3D 4K-HD video microscope as compared to a standard operating microscope. Orbitozygomatic, Supraorbital, Interhemispheric transcallosal, and sub-occipital approaches were undertaken in 8 cadaveric heads (figure 1).

    Results: Dissection times of critical structures was comparable with the 3D 4K-HD video microscope and a standard operating microscope. The low profile video microscope facilitated inversion of the operative corridor with smaller craniotomy, enhanced instrument maneuverability, wider depth of focus, and decreased obstruction in passing surgical instruments. The large monitor offered an immersive surgical experience and allowed multiple team members the same high-quality view as the primary operator. Finally, the video microscope possessed a more ergonomically favorable setup as compared to the traditional microscope, allowing the surgeon to be in a neutral position independent of operative angle.

    Conclusions: The novel 3D 4K-HD video microscope system possesses favorable optics, focal length, ergonomics, and maneuverability as compared to the traditional operating microscope. The video microscope’s shared surgical view possesses potential educational and workflow advantages. This cadaveric feasibility study justifies trial of this technology in cranial cases under an IRB.

    Patient Care: Improvements in visualization, maneuverabilty, and ergonomics affected by the 3D 4K-HD Video Microscope may facilitate improved technical surgical results and clinical outcomes. The immersive environment afforded by the system may facilitate active assistance by a greater number of operators in technically challenging cases. Moreover, complete immersion facilitates education of junior level trainees who will become operators in the future without interruption or sacrificing visualization.

    Learning Objectives: Assess the surgical potential of a novel, three-dimensional (3D), high-definition (4K-HD) video microscope system in microneurosurgical procedures.

    References: 1. Quilici PJ, Greaney EM, Quilici J, Anderson S. Laparoscopic inguinal hernia repair results: 131 cases. Am Surg. Dec 1993;59(12):824-830. 2. Cruvinel MG, Duarte JB, Castro CH, Costa JR, Kux P. Multimodal approach to rapid discharge after endoscopic thoracic sympathectomy. Acta Anaesthesiol Scand. Feb 2005;49(2):238-242. 3. McKenna RJ, Mahtabifard A, Pickens A, Kusuanco D, Fuller CB. Fast-tracking after video-assisted thoracoscopic surgery lobectomy, segmentectomy, and pneumonectomy. Ann Thorac Surg. Nov 2007;84(5):1663-1667; discussion 1667-1668. 4. Bilimoria KY, Bentrem DJ, Merkow RP, et al. Laparoscopic-assisted vs. open colectomy for cancer: comparison of short-term outcomes from 121 hospitals. J Gastrointest Surg. Nov 2008;12(11):2001-2009. 5. Shah SS, DiCristina CM, Bell LM, Ten Have T, Metlay JP. Primary early thoracoscopy and reduction in length of hospital stay and additional procedures among children with complicated pneumonia: results of a multicenter retrospective cohort study. Arch Pediatr Adolesc Med. Jul 2008;162(7):675-681. 6. Tiberio GA, Baiocchi GL, Arru L, et al. Prospective randomized comparison of laparoscopic versus open adrenalectomy for sporadic pheochromocytoma. Surg Endosc. Jun 2008;22(6):1435-1439. 7. Mamelak AN, Nobuto T, Berci G. Initial clinical experience with a high-definition exoscope system for microneurosurgery. Neurosurgery. Aug 2010;67(2):476-483. 8. Mamelak AN, Danielpour M, Black KL, Hagike M, Berci G. A high-definition exoscope system for neurosurgery and other microsurgical disciplines: preliminary report. Surg Innov. Mar 2008;15(1):38-46. 9. Mamelak AN, Drazin D, Shirzadi A, Black KL, Berci G. Infratentorial supracerebellar resection of a pineal tumor using a high definition video exoscope (VITOM®). J Clin Neurosci. Feb 2012;19(2):306-309. 10. Andaluz N, van Loveren HR, Keller JT, Zuccarello M. The One-Piece Orbitopterional Approach. Skull Base. Nov 2003;13(4):241-245. 11. Spiotta AM, Fiorella D, Vargas J, et al. Initial multicenter technical experience with the Apollo device for minimally invasive intracerebral hematoma evacuation. Neurosurgery. Jun 2015;11 Suppl 2:243-251; discussion 251. 12. Fiorella D, Gutman F, Woo H, Arthur A, Aranguren R, Davis R. Minimally invasive evacuation of parenchymal and ventricular hemorrhage using the Apollo system with simultaneous neuronavigation, neuroendoscopy and active monitoring with cone beam CT. J Neurointerv Surg. Oct 2015;7(10):752-757.